Advance Search
Volume 43 Issue S2
Dec.  2022
Turn off MathJax
Article Contents
Fan Xukai, Zhu Yucheng, Peng Tianji, Tian Wangsheng, Tang Yanze, Fan Deliang. Study on Operating Characteristics and Water Hammer Phenomenon of Lead-Bismuth Eutectic Commutator with Enclosed Structure[J]. Nuclear Power Engineering, 2022, 43(S2): 137-142. doi: 10.13832/j.jnpe.2022.S2.0137
Citation: Fan Xukai, Zhu Yucheng, Peng Tianji, Tian Wangsheng, Tang Yanze, Fan Deliang. Study on Operating Characteristics and Water Hammer Phenomenon of Lead-Bismuth Eutectic Commutator with Enclosed Structure[J]. Nuclear Power Engineering, 2022, 43(S2): 137-142. doi: 10.13832/j.jnpe.2022.S2.0137

Study on Operating Characteristics and Water Hammer Phenomenon of Lead-Bismuth Eutectic Commutator with Enclosed Structure

doi: 10.13832/j.jnpe.2022.S2.0137
  • Received Date: 2022-07-20
  • Rev Recd Date: 2022-09-01
  • Publish Date: 2022-12-31
  • In order to study the flow stability and applicability of the commutator with enclosed structure in the process of liquid lead-bismuth eutectic (LBE) medium commutation, FLUENT software combined with overlapping grid method is used to calculate and analyze the pressure and velocity fluctuations upstream of the commutator with enclosed structure in the form of three-way switching valve during commutation. The results show that in the process of commutation, the water hammer is produced when the valve element starts and stops, and the water hammer wave propagates in the pipe at the medium sound velocity, thus affecting the distribution of pressure and velocity in the pipe. The peak value of the water hammer wave is proportional to the medium density and the movement speed of the valve element, and the frequency of the water hammer wave is not affected by the movement speed of the valve element. Because the peak value of the water hammer wave is large, it is difficult for the upstream pipe of this type of commutator with enclosed structure to maintain a steady flow and threaten the safety of the device during commutation operation under LBE, so it is not suitable for LBE flow calibration device.

     

  • loading
  • [1]
    SHIMADA T, MAHADEVA D V, BAKER R C. Further investigation into a water flow rig related to calibration[J]. Flow Measurement and Instrumentation, 2010, 21(4): 462-475. doi: 10.1016/j.flowmeasinst.2010.06.003
    [2]
    JOUKOWSKI N E. Memoirs of the imperial academy society of St. Petersburg[J]. Proceedings of the American Water Works Association, 1898(24): 341-424.
    [3]
    NIKPOUR M R, NAZEMI A H, DALIR A H, et al. Experimental and numerical simulation of water hammer[J]. Arabian Journal for Science and Engineering, 2014, 39(4): 2669-2675. doi: 10.1007/s13369-013-0942-1
    [4]
    FENG T T, ZHANG D L, SONG P, et al. Numerical research on water hammer phenomenon of parallel pump-valve system by coupling FLUENT with RELAP5[J]. Annals of Nuclear Energy, 2017, 109: 318-326. doi: 10.1016/j.anucene.2017.05.049
    [5]
    胡坤, 顾中浩, 马海峰. ANSYS CFD疑难问题实例详解[M]. 北京: 人民邮电出版社, 2017: 263-264.
    [6]
    戎利建, 张玉妥, 陆善平. 铅与铅铋共晶合金手册——性能、材料相容性、热工水力学和技术(2007版)[M]. 北京: 科学出版社, 2014: 9-61.
    [7]
    吕鸣宇,张斌,裴晓迟. 流量标准装置中闭式换向器对流量测量的影响[J]. 信息系统工程,2012(8): 109,103.
    [8]
    全国流量容量计量技术委员会. 液体流量计器具检定系统表检定规程: JJG 2063—2007[S]. 北京: 中国标准出版社, 2008: 3-4.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(12)  / Tables(2)

    Article Metrics

    Article views (120) PDF downloads(20) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return