Advance Search
Volume 40 Issue 4
Aug.  2019
Turn off MathJax
Article Contents
Zou Peng, Cao Jiebao, Wang Yunbo, Tang Xiding, Kang Changhu, Yang Bin. Effect of Spectrum Variation on Activation Measurement for Neutron Fluence[J]. Nuclear Power Engineering, 2019, 40(4): 56-59.
Citation: Zou Peng, Cao Jiebao, Wang Yunbo, Tang Xiding, Kang Changhu, Yang Bin. Effect of Spectrum Variation on Activation Measurement for Neutron Fluence[J]. Nuclear Power Engineering, 2019, 40(4): 56-59.

Effect of Spectrum Variation on Activation Measurement for Neutron Fluence

  • Publish Date: 2019-08-15
  • In the reactor neutron fluence measurement, the activation detectors will suffer neutron radiation in several fuel cycles, with which neutron spectrum varies. Considering this factor, for the neutron fluence measurement was corrected for one batch of irradiation material for the domestic pressure vessel. Calculations show that the relative deviation for the weighted neutron fluence (E>1.0 MeV) correction is 1.75%, reducing 3.73% compared to the uncorrected weighted neutron fluence (E>1.0 MeV), and thus the effect of spectrum variation cannot be ignored.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (206) PDF downloads(2) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return