Zheng Junwei, Liu Yang, Deng Sheng, Ma Shu, Wang Canhui, Du Wenlong, Cui Yongle. Reason Analysis for Unsatisfactory of Accuracy and Improvement of Accuracy of On-line Boron Meter in a Nuclear Power Plant[J]. Nuclear Power Engineering, 2020, 41(2): 102-108.
Citation: Zheng Junwei, Liu Yang, Deng Sheng, Ma Shu, Wang Canhui, Du Wenlong, Cui Yongle. Reason Analysis for Unsatisfactory of Accuracy and Improvement of Accuracy of On-line Boron Meter in a Nuclear Power Plant[J]. Nuclear Power Engineering, 2020, 41(2): 102-108.

Reason Analysis for Unsatisfactory of Accuracy and Improvement of Accuracy of On-line Boron Meter in a Nuclear Power Plant

  • Publish Date: 2020-04-11
  • In order to find out the reason for the unsatisfactory of measurement accuracy of the online type boron meter (BCMS) supplied by AREVA NP GmbH, the scheme to improve the BCMS measurement accuracy was studied. According to the working principle of BCMS, the factors affecting the measurement accuracy of BCMS were analyzed in terms of the neutron measurement and total boron concentration calculation, and the measurement data of BCMS is statistically analyzed; the offline type boron meter(OFBM) with measurement accuracy higher than that of BCMS was selected as the comparison object, and the comparison of the measurement accuracy between BCMS and OFBM was made under the same statistical error analysis condition; the online type boron meter (ONBM) developed by Nuclear Power Institute of China was selected as the reference, and the quantitative analysis of the effect of the measured pipe size on the BCMS neutron count rate was made. The results show that: the unsatisfactory of measurement accuracy existed  both in the manufacture factory test and in the nuclear power plant operation of BCMS, which  was caused by the extremely low value of the cumulative neutron count rate measured by its neutron measurement device within a fixed counting time; and the loss neutron by polyethylene exists between the neutron source and the neutron detector of BCMS. A modification scheme to improve the BCMS measurement accuracy was proposed, i.e., to cut the polyethylene shielding layer and replace with the higher thermal neutron sensitivity detector .

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (375) PDF downloads(2) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return