Comparison of CPR1000 and AP1000 Rod Position Indication Systems

  • Received Date: 2009-11-18
  • Rev Recd Date: 2009-12-11
  • Available Online: 2025-07-28
  • This paper introduces the structure, the function, the digital detection principle of reactor control rod position and monitoring systems in CPR1000 and AP1000, comparing with the characteristics of the system design. The results show that the operation mode and function of AP1000 Rod position indication system are similar to that of CPR1000, but AP1000 rod position system provides higher reliability, and reduces the numbers of containment electrical penetrations and is with better characteristics than that of CPR1000, since it incorporated the redundancy design and data communication.

     